Certificate

Brand

Product Type

Instrument

Highlights

Label or Dye 6-FAM, LIZ, NED, SID, TAZ, VIC Product Line GlobalFiler™ Product Type PCR Amplification Kit Shipping Condition Dry Ice Target Loci Amelogenin, CSF1PO, D10S1248, D12S391, D13S317, D16S539, D18S51, D19S433, D1S1656, D21S11, D22S1045, D2S1338, D2S441, D3S1358, D5S818, D7S820, D8S1179, DYS391, FGA, IQC-Large, IQC-Small, SE33, TH01, TPOX, Y indel, vWA

Application

Features of the GlobalFiler IQC PCR Amplification Kit include:
• Internal quality control (IQC) system enables detection of and discrimination between amplification inhibition and DNA sample degradation and an in-sample positive amplification control, providing actionable information
• Efficient protocols minimize amplification time compared to previous-generation kits
• An optimized buffer system and expanded DNA input volume delivers maximum sensitivity for trace/low level DNA samples
• Enhanced intracolor balance simplifies interpretation of mixture samples
• The inclusion of 10 mini-STRs maximizes results from degraded samples (<220 bp)
• Contains all markers recommended for inclusion by the CODIS Core Loci Working Group, including all markers commonly used in Europe, for maximum global database compatibility
• Improved data interpretation with reduced pull-up edits and off-scale data recovery when combined with 3500 Data Collection Software v4.0 and GeneMapper ID-X Software 1.6
• Manufactured to IS0 18385 standards

Specifications

Label or Dye 6-FAM, LIZ, NED, SID, TAZ, VIC
Product Line GlobalFiler™
Product Type PCR Amplification Kit
Shipping Condition Dry Ice
Target Loci Amelogenin, CSF1PO, D10S1248, D12S391, D13S317, D16S539, D18S51, D19S433, D1S1656, D21S11, D22S1045, D2S1338, D2S441, D3S1358, D5S818, D7S820, D8S1179, DYS391, FGA, IQC-Large, IQC-Small, SE33, TH01, TPOX, Y indel, vWA

Other information

The GlobalFiler IQC kit is a robust and reliable single-amplification STR multiplex kit optimized for use with the most challenging casework samples. The kit leverages six dyes for the incorporation of additional markers, generating a highly discriminating kit for use by the forensic community. The kit contains all of the markers included in the major global databases, including 10 mini-STRs, to help deliver optimized results with even highly degraded samples.

Developed specifically for casework applications, the GlobalFiler kit contains a buffer system that delivers greater sensitivity for enhanced performance with inhibited and low-concentration DNA samples. The addition of the IQC provides more insight into sample quality to assist in distinguishing between inhibition and degradation while also providing a positive control for amplification. The GlobalFiler IQC kit utilizes the latest advances in oligo synthesis and purification, which provide a clean baseline and a balanced profile, resulting in simplified data analysis. Maintenance of the NGM Select and Identifiler primer sequences helps ensure maximum concordance with previously typed samples. In addition, the GlobalFiler IQC kit contains multiple gender markers to enable accurate typing of male samples, even highly degraded or Y-negative samples, while increased genotyping accuracy is obtained with the expansion of the allelic ladder allele ranges to include all rare alleles as described in the literature (STRbase).

Experience matters
Thermo Fisher Scientific designs and validates its reagents, instruments, and data analysis software together as an integrated system for DNA testing. Technical service scientists and field application specialists are available to answer your technical questions, review data, and make recommendations on how to perform assays and troubleshoot results. All of these resources help ensure success when using Applied Biosystems human identification solutions in your laboratory.

For licensing and limited use restrictions visit thermofisher.com/HIDlicensing.

Contents & Storage

Store at -15° to -25°C upon receipt, and 2° to 8°C after initial use for up to 6 months.

Related Products

SeqStudio™ 8 Flex Genetic Analyzer

The Applied Biosystems SeqStudio 8 Flex Genetic Analyzer offers design improvements and technological advances to the capillary electrophoresis (CE) workflow. It delivers gold-standard Sanger sequencing and fragment analysis data quality with increased flexibility, easier operation, and cloud connectivity to enable researchers to manage their workloads and work/life balance effectively. Designed for ultimate ease-of-use, this mid-throughput system offers high quality, excellent reliability, and an optimal user experience for researchers who want to work smarter in the lab.

EmbryoMap

EmbryoMap for labs assessing preimplantation embryo biopsy samples

Through evolution and innovation, the EmbryoMap solution has been analytically validated for detection of whole- and sub-chromosomal imbalances with highly reproducible copy-number, using cell line reference material and embryo biopsy samples

Samples are prepared for sequencing using the EmbryoMap Sample Prep Kit, sequenced on the Illumina MiSeq Sequencing System and data analysis and reporting performed using eMap software

Infinium KaryoMap v2

The kit contains BeadChips and reagents to perform the KaryoMap v2 assay sufficient for 16 samples.

Disclaimer: This product is labelled for Research Use Only – Not for use in diagnostic procedures.

HID Nimbus™ Presto System

The Applied Biosystems HID NIMBUS Presto System is an easy-to-use, compact instrument that combines the KingFisher Presto Purification System with an industry leading automated liquid handling workstation to precisely purify nucleic acids from lysed samples for use in sensitive downstream analyses such as DNA quantification and STR amplification.

7500 Real-Time PCR System for Human Identification with Dell Notebook D520

The Applied Biosystems™ 7500 Real-Time PCR System for Human Identification provides an advanced, validated solution for casework, databasing, and paternity applications. This system comes with a Dell Notebook D520 computer.

This instrument system provides the following:
• It is validated for use with the Quantifiler™ Human Quantification and the Quantifiler™ Y Human Male DNA Quantification Systems.
• It utilizes the Quantifiler™ kits to determine the quantity of amplifiable DNA and the potential presence of PCR inhibitors to obtain an accurate prediction of the amount of DNA input required for optimal STR amplification.
• It utilizes the Quantifiler ™ kits to quantify trace samples; real-time PCR has the widest dynamic range of any DNA detection technology.
• It provides Quantfiler™ kit results in less than 2 hours.

3500xL Genetic Analyzer for Human Identification

The 24-capillary 3500xL Genetic Analyzer sets the standard in capillary electrophoresis. The 3500-series instruments are the first genetic analyzers designed with a specific feature set and workflow for the Human Identification application. The complete product combines the instrument with Applied Biosystems™ reagents, consumables and software, as well as industry leading support, to provide an integrated HID system solution that significantly improves ease-of-use and application efficiencies.

• Increased Consistency – Reduced signal variation with factory standardization and optional in-lane normalization
• Real-Time Data Quality Assessment – On instrument data evaluation features provide rapid identification and re-injection of samples requiring additional processing
• Improved Thermal Control – Smaller oven design and improved door seal for more consistent data migration
• HID Specific Workflow – Pre-configured for Applied Biosystems™ amplification kits to simplify run setup and software navigation
• Effortless Consumable Installation – Convenient one-time use consumable packaging
• Consumable Tracking with RFID Technology – On-instrument, real-time monitoring of consumable consumption and expiration
• Enhanced Throughput – Faster data generation with 8 or 24 capillary arrays and shorter run times
• Improved Polymer Pump Design – Reduced waste and fewer bubbles for better data quality
• Simplified Instrument Installation & Operation – New solid-state laser eliminates need for high voltage wiring and external venting
• Streamlined Instrument Maintenance – HID specific performance check and maintenance scheduling tools
• Data Chain of Custody – Controlled access and tracking through Security, Audit and eSig features

EZ DNA Methylation-Gold® Kits

• Consolidated Workflow: DNA denaturation and bisulfite conversion process in one step.
• High Yield: Desulfonation and purification on a spin-column allows elution of bisulfite-converted DNA in as little as 10 µl.
• Suitable for Various Downstream Applications: Bisulfite-converted DNA can be robustly PCR amplified for downstream analyses including endonuclease digestion, sequencing, microarrays, etc.

Next Generation Sequencing System – NovaSeq X Series

NovaSeq X also significantly reduces waste and environmental impact, reflecting Illumina’s commitment to using its technology to support the health of people and the planet. NovaSeq X features a 90% reduction in packaging waste and weight and 50% reduction in plastic usage compared to NovaSeq 6000.

 

Zymot multi 3mL

Zymot with simple operation process, helps to collect high-quality sperm, improve the efficiency of Assisted Reproduction (IVF, IUI, ICSI).

Zymot multi 850uL

Zymot with simple operation process, helps to collect high-quality sperm, improve the efficiency of Assisted Reproduction (IVF, IUI, ICSI).