Model: Iseq
Manufacturer: Illumina/USA
– The smallest, most affordable Illumina sequencing system delivers fast and efficient low-
throughput sequencing for virtually any lab.
– Rapid Data Generation: Run smaller projects on a dedicated, low-throughput instrument with fast turnaround times
– Convenient Operations: Control the sequencing process from beginning to end and maintain an independent sequencing schedule instead of outsourcing
– Run Time: 9–17.5 hours;
– Maximum Output 1.2 Gb;
– Maximum Reads Per Run 4 million;
– Maximum Read Length 2 × 150 bp
– Instrument Dimensions 42.5 cm × 30.5 cm × 33 cm (16.8 in × 12 in × 13 in)
– Weight 15.9 kg (35 lb)
Reads length | Total Time | Output |
1 × 36 bp | 9 hours | 144 Mb |
1 × 50 bp | 9 hours | 200 Mb |
1 × 75 bp | 10 hours | 300 Mb |
2 × 75 bp | 13 hours | 600 Mb |
2 × 150 bp | 17.5 hours | 1.2 Gb |
Details: https://sapac.illumina.com/systems/sequencing-platforms/iseq.html
TaqMan Fast Advanced Master Mix cung cấp khả năng định lượng chính xác và độ tin cậy trong thời gian ngắn trên các nền tảng thiết bị qPCR.
Công cụ phòng lab tiên tiến nhất dành cho nghiên cứu khoa học.
Công nghệ giọt treo âm thanh Echo acoustic là bước đột phá cho giải pháp tự động hóa với khả năng không dính, không nhiễm mẫu, độ chính xác và tốc độ cao trong thao tác hút nhả mẫu lỏng sử dụng năng lượng âm thanh (Với mẫu từ 2.5 đến 25 nL).
Sóng âm thanh vận chuyển mẫu dưới dạng giọt treo với thể tích mẫu chính xác từ đĩa chứa cho tới đĩa đích treo. bên trên.
Với dải sản phẩm rộng bao gồm:
Echo 650 Liquid Handler
Echo 655 Liquid Handler
Echo 655T Liquid Handler
Echo 650T Liquid Handler
Echo 525 Liquid Handler
Echo 555 Liquid Handler
Designed for your evolving workflow priorities Representing the best of what made Biomek an industry leading liquid handler—combined with enhancements suggested by customers around the globe—the Biomek i7 Automated Workstation has been designed to optimize workflows and increase walk-away in mid- to high-throughput labs.
Viral DNA and RNA from all biological fluids:
– Quick recovery of viral RNA from plasma, serum and other samples.
– Omits the use of organic denaturants and proteases.
– High-quality viral RNA is ready for RT-PCR, sequencing, etc.
Clean-up PCR and other enzymatic reactions in as little as 2 minutes:
– Clean and concentrate up to 5 μg DNA with ≥ 6 μl elution in as little as 2 minutes with 0 μl wash residue carryover.
– Column design allows DNA to be eluted at high concentrations into minimal volumes of water or TE buffer.
– Eluted DNA is well suited for use in PCR, DNA sequencing, DNA ligation, endonuclease digestion, RNA transcription, radiolabeling, arrays, etc.
The Health Statistics shows that there are 200,000 tuberculosis patients and 30,000 deaths every year in Vietnam. The main cause of human tuberculosis is M. Tuberculosis, also called as tuberculosis bacteria.
GeneProof Mycobacterium tuberculosis PCR Kit applies PCR technology to detect DNA of Mycobacterium tuberculosis in samples. The kit has CE-IVD certification for in vitro Diagnostic Use.
TruSight Tumor 170 Kit includes library preparation reagent set and uses next-generation sequencing (NGS) technology to provide a comprehensive assessment of 170 genes that are commonly related to mutations in solid tumors and somatic variants.
Model: iScan
Manufacturer: Illumina / USA
Fully automated Micro-array System
Công nghệ Microarray BeadArray được sử dụng trong các sản phẩm array của Illumina và các máy scanner trong một loạt các ứng dụng phân tích DNA và RNA.