Certificate

Brand

Thermo Fisher Scientific

Product Type

Instrument

Highlights

For Research Use Only

The Applied Biosystems™ 7500 Real-Time PCR System for Human Identification provides an advanced, validated solution for casework, databasing, and paternity applications. This system comes with a Dell Notebook D520 computer.

This instrument system provides the following:
• It is validated for use with the Quantifiler™ Human Quantification and the Quantifiler™ Y Human Male DNA Quantification Systems.
• It utilizes the Quantifiler™ kits to determine the quantity of amplifiable DNA and the potential presence of PCR inhibitors to obtain an accurate prediction of the amount of DNA input required for optimal STR amplification.
• It utilizes the Quantifiler ™ kits to quantify trace samples; real-time PCR has the widest dynamic range of any DNA detection technology.
• It provides Quantfiler™ kit results in less than 2 hours.

Specifications

Format 96-well Plate
Thermal Accuracy 0.25°C (35°C to 95°C after 3 min.)
Sample Ramp Rate ± 1.1°C⁄s
Sensitivity 1 Copy of RNase P gene (Human Genomic DNA)
Temperature Range (Metric) 4 to 100°C
Reaction Volume Range 20-100 µl
Passive Reference Dye ROX (Separate Tube), No ROX, ROX (Pre-mixed)
Dynamic Range 9 Logs
Calibrated Dye SYBR™ Green I, ROX™, Texas Red™, NED™, JOE™, Cy3™, Cy5™, VIC™, FAM™, TAMRA™
High-throughput Compatibility Multiplexing
For Use With (Equipment) 7500 System
Thermal Uniformity 0.50°C (after 30 s)
Reaction Speed Standard
Throughput 4 to 5-96-well Plates per 8-hr day
Optics CCD Camera, 5 Excitation Filters, Tungsten-halogen Lamp, 5 Emission Filters
Thermal Cycling System Peltier-based System
Dimensions Width 34 cm (13.39 in.), Depth 45 cm (17.72 in.), Height 49 cm (19.29 in.)
External Computer Dell Notebook D520
Software Compatibility GeneMapper™ ID v3.2, 7500 System Software, HID Real Time PCR Analysis Software v1.1
Precision 99.7% Confidence (5000 & 10000 Copies)
Voltage 120 V
Electrical Requirements 950 W
Peak Block Ramp Rate 2.5°C⁄s
Weight 75 lb.

Other information

Built for Performance
The 7500 system for Human Identification includes SDS v.1.2.3 software which is validated to run Quantifiler™ Human DNA and Quantifiler™ Y Human Male DNA quantification kits. SDS v1.2.3 is a powerful, versatile software that includes plate set-up wizards and automated analysis tools that make data processing easier. Its advanced data viewing capabilities make analysis less time consuming. The instrument is a powerful, five-color platform that is calibrated for the broadest range of dyes available: FAM™⁄SYBR™ Green I, VIC™⁄JOE™, TAMRA™⁄CY3, ROX™⁄Texas Red, and CY5 dyes. Its specialized optical system enables easy and accurate calibration to new dyes without requiring the addition of new filter sets and its advanced multi-componenting algorithm minimizes spectral crosstalk making the instrument superior for multiplexing.

Complete Validated Solution
Applied Biosystems™ offers a complete solution for your human identification needs. Our system includes DNA quantification kits, a range of AmpFLSTR™ STR kits, instrumentation, software, and consumables. All reagents are developed in accordance with guidelines from leading worldwide forensic organizations including: SWGDAM, DAB, CODIS, ENFSI, Interpol, and GITAD. The system has been internally validated by Applied Biosystems™ following DAB⁄SWGDAM guidelines for use with Quantifiler™ Human Quantification System and Quantifiler™ Y Human Male DNA Quantification System making the 7500 system suitable for casework, paternity, and databasing laboratories.

EXPERIENCE MATTERS™
When you partner with Applied Biosystems™ you gain access to the extensive knowledge and experience of our forensic support team and training resources dedicated to Human Identification laboratories. Our HID University™ provides continuing education for DNA analysts, our support and Applications Scientists offer over 100 years combined forensic experience, and our extensive network of Field Service Engineers provide technical assistance with instrumentation.

Related Products

AutoMate Express™ Forensic DNA Extraction System, with service install

The AutoMate Express Forensic DNA Extraction System is an easy to use, robust bench-top instrument that utilizes the PrepFiler Express and PrepFiler Express BTA chemistries packaged in pre-filled, foil sealed cartridges. We have designed the PrepFiler chemistry specifically to improve the quantity and quality of DNA isolated from forensic samples, thereby increasing the potential to obtain maximum information from downstream STR analysis.

ProFlex™ 96-well PCR System

The ProFlex 96-well PCR system is the latest in our line of Applied Biosystems thermal cyclers. The ProFlex system combines the reliability and performance you’ve come to expect from Applied Biosystems instruments with the flexible configuration and control features that adapt to your research needs.

The ProFlex 96-well PCR system allows you to:
• Interchange the 96-well 0.2-mL block with another block type if throughput needs change
• Access the system remotely (and conveniently) through a mobile app
• Program the instrument in seconds with a simple-to-use touchscreen interface
• Simulate an old instrument with Thermal Simulation modes
• Optimize PCR quickly and efficiently with better-than-gradient VeriFlex blocks

3500xL Genetic Analyzer for Human Identification

The 24-capillary 3500xL Genetic Analyzer sets the standard in capillary electrophoresis. The 3500-series instruments are the first genetic analyzers designed with a specific feature set and workflow for the Human Identification application. The complete product combines the instrument with Applied Biosystems™ reagents, consumables and software, as well as industry leading support, to provide an integrated HID system solution that significantly improves ease-of-use and application efficiencies.

• Increased Consistency – Reduced signal variation with factory standardization and optional in-lane normalization
• Real-Time Data Quality Assessment – On instrument data evaluation features provide rapid identification and re-injection of samples requiring additional processing
• Improved Thermal Control – Smaller oven design and improved door seal for more consistent data migration
• HID Specific Workflow – Pre-configured for Applied Biosystems™ amplification kits to simplify run setup and software navigation
• Effortless Consumable Installation – Convenient one-time use consumable packaging
• Consumable Tracking with RFID Technology – On-instrument, real-time monitoring of consumable consumption and expiration
• Enhanced Throughput – Faster data generation with 8 or 24 capillary arrays and shorter run times
• Improved Polymer Pump Design – Reduced waste and fewer bubbles for better data quality
• Simplified Instrument Installation & Operation – New solid-state laser eliminates need for high voltage wiring and external venting
• Streamlined Instrument Maintenance – HID specific performance check and maintenance scheduling tools
• Data Chain of Custody – Controlled access and tracking through Security, Audit and eSig features

3500 Genetic Analyzer for Human Identification

The 3500 analyzer is shipped with the following system components:

• Capillary Electrophoresis instrument.
• 3500 (8-capillary) array and POP™ polymer
• Human identification reagents and other consumables for system qualification.
• Dell™ computer workstation with flat-screen monitor.
• Integrated software for instrument control, data collection, quality control, and basecalling or sizing of samples.

Image Tampering Detection and Source Camera Identification

Overview

Amped Authenticate is a software application for forensic image authentication, tampering detection, and camera ballistics on digital images. This product is the only image authentication software on the market that offers a complete suite of powerful tools to exploit the data behind digital images, allowing for the analysis of image integrity, authenticity, metadata, source and history, and detection of tampering prior to its use as intelligence and evidence. With a single product, several tests can be performed to determine if an image has been manipulated as well as verify if a photo was taken from a specific device.

Batch Convert Unplayable Videos

Overview

Amped DVRConv is the easiest way to automatically batch convert unplayable video files. Videos from proprietary CCTV/DVR systems, dashcams, body worn cameras, and any other video source can now be converted without effort. With Amped DVRConv, you just drag, drop, and you’re done. This is an ideal tool for technicians tasked with converting a great number of surveillance videos in various proprietary formats, speeding up the triage in cases such as major investigations.

CCTV Converter and Player for Investigators

Overview

Amped Replay is an enhanced video player that allows investigators, frontline officers, first responders, security personnel and CCTV operators to conduct a quick first-level analysis of their videos, with easy conversion, quick corrections, redaction, and annotation functions, as well as a report, ideal for case building and disclosure. It includes Amped Software’s powerful DVR video conversion engine to view video without the need for other non-compatible, legacy, or proprietary player software. Its easy-to-use interface means no advanced skills are required to achieve professional results in the presentation of evidence, whether used as part of a case, forwarded to another unit or intelligence analysts, or sent to the media for identification. With Amped Replay, organizations are reassured that video is processed correctly at all levels, using validated forensic tools.

Hot Shot™ Cyanoacrylate Fuming

Product Information

Model: HotShot Fingerprint Developer

Manufacturer: Lynn Peavey

Origin: United States

Peavey-Print: Super Glue™

Product Information

Model: Super Glue

Manufacturer: Lynn Peavey

Origin: United States

Fold-A-Lab kit-portable sauna cabinet

Product Information

Model: Original Fold-A-Lab Kit

Manufacturer: Lynn Peavey

Origin: United States