Certificate

Brand

Illumina

Product Type

Instrument

Highlights

The system combines clustering, amplification, sequencing and analysis of results in a single machine system.

Model: MiSeq
Manufacturer: Illumina/USA
– The MiSeq System combines cluster generation, amplification, sequencing and data analysis on a single system
– The system is most widely used, with next-generation sequencing technology –  Sequencing by Synthesis – SBS

Application

– Resequencing whole genome (Resequencing), small genome (small genome sequencing)
– Targeted sequencing
– Amplicon sequencing
– HLA Sequencing (HLA Sequencing)
De novo sequencing of both DNA and RNA genomes
– Sequencing 16S RNA applied in Metagenomics analysis, identifying bacterial pathogens
– mRNA sequencing; Small RNA
– Able to clearly detect mutations, serving in cancer diagnosis and targeted treatment
– Check clones (clone checking)
– Capable of applying to bloodline determination, chromosomal testing (PGS), preimplantation genetic diagnosis (PGS), criminal science

Specifications

MiSeq System features:

– Maximum Output: 7.5-8.5 Gb within 39 hours (paired-end sequencing of 250 bp) when using MiSeq Reagent Kit v2; 13.2-15 Gb within 56 hours (paired-end sequencing of 300 bp) when using MiSeq Reagent Kit v3
– Data quality: Quality Score > Q30 (99.9% accuracy)
– Ability to paired-end sequencing of 2×300 bp.

Power of the MiSeq system:
– Sequencing time when using the MiSeq Reagent Kit v2:

  • 1 x 36 bp ≤ 4 hours with the output of 540-610 Mb
  • 2 x 25 bp ≤ 5.5 hours with the output of 750-850 Mb
  • 2 x 150 bp ≤ 24 hours with the output of 4.5-5.1 Gb
  • 2 x 250 bp ≤ 39 hours with the output of 7.5-8.5 Gb

– Sequencing time when using the MiSeq Reagent Kit v3:

  • 1 x 75 bp ≤ 21 hours with the output of 3.3-3.8 Gb
  • 2 x 300 bp ≤ 56 hours with the output of 13.2-15 Gb

See more at: https://sapac.illumina.com/systems/sequencing-platforms/miseq.html

 

Other information

Supplier

ILLUMINA

Related Products

3500xL Dx Genetic Analyzer

The Applied Biosystems™ 3500 Series Genetic Analyzers are specifically designed to support the demanding performance needs of validated and regulated environments while retaining the unsurpassed application versatility that life science researchers expect. The 24-capillary 3500xL Genetic Analyzers continue to set the standard in capillary electrophoresis.

3500xL Genetic Analyzer

The 3500xL Genetic Analyzer is a 24-capillary sequencing platform that can be used for a wide variety of applications, including de novo sequencing and resequencing (mutational profiling), as well as microsatellite analysis, MLPA™, LOH, MLST, and SNP validation or screening. The majority of applications can be run on a single polymer and capillary array.

EmbryoMap

EmbryoMap for labs assessing preimplantation embryo biopsy samples

Through evolution and innovation, the EmbryoMap solution has been analytically validated for detection of whole- and sub-chromosomal imbalances with highly reproducible copy-number, using cell line reference material and embryo biopsy samples

Samples are prepared for sequencing using the EmbryoMap Sample Prep Kit, sequenced on the Illumina MiSeq Sequencing System and data analysis and reporting performed using eMap software

GlobalFiler™ Express PCR Amplification Kit

The GlobalFiler Express PCR Amplification Kit is the first 6-dye, 24-locus STR kit that combines maximum compatibility with global databasing loci standards, with dramatically reduced amplification time and superior discrimination power, to enable forensic DNA labs worldwide to maximize information recovery and improve overall efficiency. The GlobalFiler Express kit is part of a fully integrated and validated forensic DNA workflow backed by best-in-class global training, service, and support. This kit is optimized for database and single-source samples; for casework samples, please see our GlobalFiler PCR Amplification Kit.

EZ DNA Methylation-Gold® Kits

• Consolidated Workflow: DNA denaturation and bisulfite conversion process in one step.
• High Yield: Desulfonation and purification on a spin-column allows elution of bisulfite-converted DNA in as little as 10 µl.
• Suitable for Various Downstream Applications: Bisulfite-converted DNA can be robustly PCR amplified for downstream analyses including endonuclease digestion, sequencing, microarrays, etc.

Next Generation Sequencing System – NovaSeq X Series

NovaSeq X also significantly reduces waste and environmental impact, reflecting Illumina’s commitment to using its technology to support the health of people and the planet. NovaSeq X features a 90% reduction in packaging waste and weight and 50% reduction in plastic usage compared to NovaSeq 6000.

 

BRCAaccuTest™ & BRCAaccuTest™PLUS

BRCAaccuTest™ PLUS with CE-IVD certificate for HBOC Breast/Ovarian Cancer Test

Zymot multi 3mL

Zymot with simple operation process, helps to collect high-quality sperm, improve the efficiency of Assisted Reproduction (IVF, IUI, ICSI).

Next-Generation Sequencing System – NextSeq 2000

 The NextSeq 2000 Sequencing System uses patterned flow cells similar to those that power the NovaSeq™ 6000 System. The result is a highly flexible and scalable benchtop system that offers the highest cluster density flow cell of any on-market NGS system to date, driving down the cost per gigabase (Gb) of the sequencing run.

Basic Yellow 40

Product Information

Model: Basic Yellow

Manufacturer: Lynn Peavey